Multi V 5 Cooling Only Outdoor Units Specifications 460V 10 ARUV121DTE5 ARUV121DTE5 RT Combination Unit Model Name Independent Unit Cooling (Norminal) Capacity Cooling (Rated) Input Cooling (Norminal) Cooling (Rated) EER (Norminal) EER (Rated) Power Factor Rated Color Exterior RAL code Heat Exchanger Type Piston Displacement Compressor Number of Revolution Motor Output x Number Starting Method Oil Type Type Motor Output x Number Fan Air Flow Rate(High) Pipe Connctions Drive Discharge Liquid Gas Dimensions(W x H x D) Net Weight Sound Pressure Level (Cooling) Sound Power Level (Cooling) High pressure protection Protection Compressor/Fan Devices Inverter Communication Cable (VCTF-SB) Btu/h kW Btu/h kW kW kW - cm3/rev rev/min W x No. Precharged Amount Control 62.1 W 3,600 5,300 × 1 Direct On Line FVC68D(PVE) Propeller fan 1,200 × 1 m3/min 240 × 1 ft3/min Side / Top mm(inch) mm(inch) mm inch kg lbs dB(A) dB(A) 8,476 × 1 DC INVERTER TOP 12.7(1/2) 28.58(1-1/8) (930 × 1,690 × 760) × 1 (36-5/8 × 66-17/32 × 29-29/32) × 1 200 × 1 441 × 1 59.0 79.0 High pressure sensor / High pressure switch Over-heat protection / Fan driver overload protector Over-heat protection / Over-current protection No.×༅ 2C × 1.0 ~ 1.5 kg lbs R410A 10.0 22.0 Electronic Expansion Valve Refigerant name Refigerant 120,000 35.2 114,000 33.4 8.51 7.86 4.14 4.25 0.93 Warm Gray / Dawn Gray NL503K / NA507K Wide Louver Plus Hermetically Sealed Scroll Note 1. Due to our policy of innovation some specifications may be changed without notification. 2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that. 3. Power factor could vary less than ±1% according to the operating conditions. 4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. 5. Performances are based on the following conditions : • *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB • Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero. 6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination. The recommended ratio is 130%. 7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5) 30 Gravity point 58 [mm(inch)] Ø 22.2 (7/8) Ø 28.58 (1-1/8) Ø 9.52 (3/8) Ø 12.7 (1/2) 8 10 RT Gas pipe Cooling Only Liquid pipe System Multi V 5 Cooling Only Outdoor Units Dimensions ARUV121DTE5