Multi V 5 Cooling Only
Outdoor Units
Specifications
460V
10
ARUV121DTE5
ARUV121DTE5
RT
Combination Unit
Model Name
Independent Unit
Cooling (Norminal)
Capacity
Cooling (Rated)
Input
Cooling (Norminal)
Cooling (Rated)
EER (Norminal)
EER (Rated)
Power Factor
Rated
Color
Exterior
RAL code
Heat Exchanger
Type
Piston Displacement
Compressor
Number of Revolution
Motor Output x Number
Starting Method
Oil Type
Type
Motor Output x Number
Fan
Air Flow Rate(High)
Pipe
Connctions
Drive
Discharge
Liquid
Gas
Dimensions(W x H x D)
Net Weight
Sound Pressure Level (Cooling)
Sound Power Level (Cooling)
High pressure protection
Protection
Compressor/Fan
Devices
Inverter
Communication Cable (VCTF-SB)
Btu/h
kW
Btu/h
kW
kW
kW
-
cm3/rev
rev/min
W x No.
Precharged Amount
Control
62.1
W
3,600
5,300 × 1
Direct On Line
FVC68D(PVE)
Propeller fan
1,200 × 1
m3/min
240 × 1
ft3/min
Side / Top
mm(inch)
mm(inch)
mm
inch
kg
lbs
dB(A)
dB(A)
8,476 × 1
DC INVERTER
TOP
12.7(1/2)
28.58(1-1/8)
(930 × 1,690 × 760) × 1
(36-5/8 × 66-17/32 × 29-29/32) × 1
200 × 1
441 × 1
59.0
79.0
High pressure sensor / High pressure switch
Over-heat protection / Fan driver overload protector
Over-heat protection / Over-current protection
No.×༅
2C × 1.0 ~ 1.5
kg
lbs
R410A
10.0
22.0
Electronic Expansion Valve
Refigerant name
Refigerant
120,000
35.2
114,000
33.4
8.51
7.86
4.14
4.25
0.93
Warm Gray / Dawn Gray
NL503K / NA507K
Wide Louver Plus
Hermetically Sealed Scroll
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
30
Gravity point
58
[mm(inch)]
Ø 22.2 (7/8)
Ø 28.58 (1-1/8)
Ø 9.52 (3/8)
Ø 12.7 (1/2)
8
10
RT
Gas
pipe
Cooling Only
Liquid
pipe
System
Multi V 5 Cooling Only
Outdoor Units
Dimensions
ARUV121DTE5